Heat Transfer Enhancement in a Rectangular Duct with Rib Turbulators
Abstract
The present paper is a review of research work on heat transfer enhancement in a rectangular duct withrib turbulators. In the present paper emphasis is given to works dealing with rib turbulators because according to the recent studies, these are known to be economic tool in the field of heat transfer enhancement. The use of rib turbulator has been found to be an efficient method of enhancing the heat transfer to fluid flowing in the rectangular duct. Detailed information about the heat transfer and flow characteristics in ribbed ducts is very important in proper designing of rectangular ducts, heat exchangers and cooling systems of gas turbine engines. The application of rib turbulator in the form of fine wires of different shapes has been recommended to enhance the heat transfer coefficient by several investigators. It has been found that the main thermal resistance to the convective heat transfer is due to the presence of laminar sub layer on the heat-transferring surface. The ribs break the laminar sub layer and create local wall turbulence due to flow separation and reattachment between consecutive ribs, which reduce the thermal resistance and greatly enhance the heat transfer. However, the use of rib turbulator results in higher friction and hence higher pumping power requirements. The thermo-hydraulicperformance of rectangular duct withrib turbulatorsdepends on the various factorssuch as flow conditions, geometry of rib and different configurations.
References
TabishAlam, R.P. Saini ans J.S. Saini, Use of turbulators for heat transfer augmentation in an air ductA review, Renewable Energy, 62 (2014), 689-715.
R.L.Webb, E.R.G.Eckort and K.JGoldstein, Heat transfer and friction in tubes with repeated rib roughness, Int J Heat Mass Tran. 14(1971), 601-17.
R.J.Firth and L.Meyer, A comparison of the heat transfer and friction factor performance of four different types of artificially roughened surface, International Journal of Heat and Mass Transfer, 26(2)(1983), 175183.
A.K.Bhargava and G.Rizzi, A solar air heater with variable flow passage width, Energy Convers. Mgmt., 30(1990), 329-332.
A.Hegazy Adel, Optimization of flow channel depth for conventional flat- plate solar air heaters, Enewable Energy, 7(1996), 15-21.
J.C.Han and J.S.Park, Developing heat transfer in rectangular channels with rib turbulators, Int. J. Heat and Mass transfer, 31(1988), 183-195.
Hsieh Shou-shing, Shih Huei-Jan and Hong Ying-Jong, Laminar forced convection from surface-mounted ribs, Int. J. Heat and Mass transfer, 33(1990), 1987-99.
Hong Ying-Jong and HseishShouShing, An experimental investigation of heat transfer characteristics for turbulent flow over staggered ribs in a square duct, Experimental thermal and fluid science, 4(1991),714-722.
Hwang Jenn-Jiang and Liou Tong-Miin, Heat transfer and friction in a low-aspect-ratio rectangular channel with staggered slit-ribbed walls, International journal of rotating machinery, 4(1998), 283-291.
GaoXiufang and Sunden Bengt, Heat transfer and pressure drop in rib roughened rectangular duct, Experimental thermal fluid sciences. 24(2001), 25-34.
Murata Akira and Mochizuki Sadanari, Comparison between laminar and turbulent heat transfer in a stationary square duct with transverse or angled rib turbulators, Int. J. Heat and Mass transfer, 44(2001), 1127-1141.
S.W.Ahn, The effects of roughness types on friction factors and heat transfer in roughened rectangular duct, Int. J. Heat and Mass transfer, 28(2001), 933-942.
P.R.Chandra, C.R.Alexander and J.C.Han, Heat transfer and friction behaviors in rectangular channels with varying number of ribbed walls, Int. J. Heat and Mass transfer, 46(2003), 481495.
Tanda Giovanni, Heat transfer in rectangular channels with transverse and V-shaped broken ribs, Int. J. Heat and Mass transfer, 47(2004), 229243.
Tariq Andallib, Singh Kamlesh and P.K.Panigrahi, Detailed measurement of heat transfer and flow characteristics in rectangular duct with rib turbulators mounted on the bottom surface, Engineering Turbulence Modelling and Experiments, 5(2002), 445-454.
S.Y.Won and P.M.Ligrani, Comparisons of flow structure and local Nusselt numbers in channels with parallel- and crossed-rib turbulators, 47(2004), 15731586.
Wang Lieke and Sunden Bengt, An experimental investigation of heat transfer and fluid flow in a rectangular duct with broken v-shaped ribs, Experimental Heat Transfer, 17(2004), 243259.
S.B.Bopche and M.S.Tandale, Experimental investigations on heat transfer and frictional characteristics of a turbulator roughened solar air heater duct, Int J Heat and Mass Transfer, 52(2009), 283448.
VS.Hans, RP.Sainiand JS.Saini, Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple V-ribs, Solar Energy, 84(2010), 89891.
A.Lanjewar, JL.Bhagoria and RM.Sarviya, Heat transfer and friction in solar air heater duct with W-shaped rib roughness on absorber plate, Energy, 39(2011), 4531-41.
S.Chaudhary, Varun and M.K.Chauhan, Heat transfer and friction factor characteristics using continuous M shape ribs turbulators at different orientation on absorber plate solar air heater, Int J energy and environment, 3(1)(2012), 33-48.
AK.Sharma and NS.Thakur, CFD based fluid flow and heat transfer analysis of a v- shaped roughened surface solar airheater, Int J Engineering Science and Technology, 4(5)(2012), 2115-21.
B.N.Prasad, Ashwini Kumar and K.D.P.Singh, Optimization of thermo hydraulic performance in three sidesartificially roughened solar air heaters, Solar Energy, 111(2015), 313319.